Current location - Loan Platform Complete Network - Foreign exchange account opening - How to connect Delixi XM series digital temperature indicating regulator?
How to connect Delixi XM series digital temperature indicating regulator?
XMT XMTA XMTD XMTE XMT-DA series

Digital temperature display

accommodometer

operation instruction

Please identify the registered trademark: YURON?

Beijing Yulong instrument co., ltd

I. Overview

— 1 —

XMT series digital display instruments are a new generation of industrial automatic detection instruments developed in recent years.

— 2 —

Measurement and control instrument, which adopts advanced medium and large scale integrated circuits and applies unique electrical nonlinear correction technology. The setting forms include analog knob setting and digital dip switch setting. And XMZ. XMT series conforming to moving coil instruments and XMZA, XMTA, XMTD and XMTE series designed according to international din standards. Compared with the traditional moving coil instrument and electronic regulator, it has the advantages of high display accuracy, good temperature control performance, strong earthquake resistance, good reliability, clear reading, negligible difference and long-distance observation. Light weight, convenient installation, etc. There are many adjustment forms, such as two-position, three-position, time ratio, thyristor continuous adjustment, PID adjustment and so on. , and can increase the over-limit alarm output function according to the needs of users. It is an updated product of XC series, TD series and TE series temperature control instruments, which can be widely used in plastic machinery, packaging machinery, food machinery, textile machinery, metallurgy, refrigeration, chemical industry, medical treatment and other industries, and is suitable for -200 ~ 65438.

The measuring and adjusting range of the instrument shall be selected in the following table according to the matched temperature sensing elements:

(Table 1)

Equipped with temperature sensing elements.

Graduation number

Range℃

solve

Nickel-chromium-copper-nickel alloy

E

(EA- 2)

0~300、0~400、0~600

Nickel-chromium-nickel-silicon alloy

K(EU-2)

0~400、0~600、0~800、0~ 1300

electric current

hot

idol

Platinum rhodium–platinum

S (lb -3)

700~ 1600

1℃

Copper resistance

Cu50

(G)

–50.0~ 150.0 0~50.0

0~ 100.0 0~ 150.0

– 199.9~ 199.9、0~ 199.9

0. 1℃

hot

electric current

block

RTD

Pt 100

(BA 1 BA 2)

0~300、0~400、0~600

1℃

Second, musical instruments

(Table 2)

— 3 —

model

Matching sensor

Working energy

XMZ- 10□

XMZD-200□

Temperature display

XMT- 10□ (m)

XMTA-200□ (m)

XMTD-200□ (m)

XMT- up to -800□ m

Temperature display

Adjust according to position

XMT- 1 1□

XMTA-20 1□ (m)

Temperature display and location type

Adjust additional overrun alarm

XMT- 12□(F)

XMTA-220□(F)

XMTD-220□(F)

Temperature display and upper and lower three digits

Type adjustment, instrument with "F"

Upper and lower limits of relay output

XMT- 13□ (m)

XMTA-230□ (m)

XMTD-230□M

XMTE-230□M

XMT- up to -830□ m

Temperature display

And time proportion adjustment.

XMT- 16□

XMTA-260□

XMTD-260□

Temperature display controllable

Silicon phase shift trigger adjustment

XMT- 17□

XMTA-270□

Temperature display controllable

Silicon zero-crossing trigger regulation

XMT- 18□

XMTA-280□

Temperature display three-phase tank

SCR zero-crossing trigger regulation

XMT- 19□

XMTA-290□

If "□" is "1"

Thermocouples shall be provided.

English (East Asia -2)

K(EU-2)

S (lb -3)

If □ is "2"

Thermal resistance shall be provided.

Gu50 (g)

Pt 100(BA 1 BA2)

If "□" is "3"

Input voltage "mV" signal

If "□" is "4"

Input resistance "ω" signal

If "□" is "5"

Input current "mA" signal

Temperature display, PID adjustment

Note: In general, the instrument is set by the knob. If "m" is added after the model, the instrument is set by the digital dip switch.

Third, the main technical indicators

— 4 —

Overall dimensions and installation hole dimensions of the instrument (Table 3)

Instrument model

Overall dimension (B×H×L)

Opening size (B×H)

XMT、XMZ - 1□□

160×80× 150

152+ 1×76+ 1

XMT-8□□□

60× 120× 150

55+ 1× 1 15+ 1

MXTA、XMZA

96×96× 150

92+ 1×92+ 1

XMTD、XMZD

72×72× 150

67+ 1×67+ 1

XMTE

48×96× 120

42+ 1×90+ 1

Note: B is the front width of the instrument, H is the height, and L is the depth length of the instrument in mm..

1. display mode: XMZ, xmt–1□ series, XMZA, XMTA series, 3( 1/2) digit digital tube displays the measured value. XMTE, XMTD, xmt–8 □□□ series, 3-digit digital tube displays the measured value.

2. Display error: ≤ 1% 1, (or user-defined error ≤ 0.5%1);

3. Set point error: ≤ 1% 1 word;

4. Control point switching difference: ≤ 0.5%

5. Cold end compensation: the error within 0~40℃ is less than 2℃;

6. Time scale adjustment: the scale band is 3 ~ 6%, and the period is 3010s; ;

7. Overlimit alarm: when the measured signal exceeds the set value, the alarm output point is 2- 10% (full scale), and the alarm elimination range is ≤1;

8. Output pulse signal: phase-shifting pulse or zero-crossing trigger pulse with amplitude greater than 3V and width greater than 40us;

9. Adjustment of P, I and D: (1) Output 0 ~ 10 mA; (2) The load is 80080Ω; (3)P (proportional band) 4%; (4)I (integration time) 2.5 minutes; ; (5)D (differential time) 30S;;

10. output contact capacity: AC 220V, 3A (resistive load) or 1A (inductive);

1 1. temperature coefficient: it deviates from 20 2℃ in the range of 0~50℃, and its temperature coefficient is less than 0.05%/℃;

12. Working power supply: AC 220 V 10%, 50Hz, power consumption less than 5w;

13. Working environment: no corrosive gas, temperature 0~50℃, relative humidity 30 ~ 85℃;

14. overall dimensions and opening dimensions: see table 3;

15. Weight: about 0.8kg ..

Fourth, the use and adjustment

— 5 —

1. Check whether the scale number of the instrument is the same as that of the temperature sensing element;

2. The instrument equipped with thermocouple may not be connected with15Ω external resistor, which will not affect the accuracy. If the distance is far away, the thermocouple and the instrument should be connected with corresponding compensation lines, and the polarity cannot be reversed, so as not to affect the accuracy; The installation position of the sensor should correctly and timely reflect the temperature rise and fall of the measured object; If it is found that the instrument is abnormal, check whether the sensor connection is open (the instrument has disconnection protection function); Instruments equipped with thermal resistors are generally not connected with three 5 Ω external resistors, but the specifications and lengths of the three connecting wires of thermal resistors should be the same. If the lead is long, it is recommended to use an external resistor, and this should be stated when ordering.

3. Insert the instrument into the mounting hole, and properly tighten the mounting screws on the upper and lower sides. Be careful not to tighten the screws too tightly to avoid damaging the shell.

4.XmZ, XMZA and XMZD models: Connect the power supply and temperature sensing element, and display the measured temperature value without adjustment.

5. xmt–101,102, xmta–2001,2002, xmtd–2001,2002, xmt–800/kloc-0. At this time, the digital display shows the actual temperature value of the measured object. When the actual value is lower than the set value, the green light is on, and the total low-pass and total high-break of the output relay are turned on. When the actual value reaches or exceeds the set value, the red light is on, and the total Qualcomm and the total low break of the output relay are turned on. For the instrument set with dip switch, just dial the dip switch to the required temperature value after wiring, and the control state is the same as above.

6.xmt- 12 1 (female), 122 (female), xmta-220 1 (female), 2202 (female), xmtd-220 1 (. Turn the switch to the "upper limit setting" position and turn the corresponding upper limit setting knob, and the required upper limit temperature value will be displayed at this time; Then turn the switch to the "measurement" position, and the digital display shows the actual temperature value of the measured object. When the actual value is lower than the lower limit set value, the green light is on, and the upper limit relay is always low on and high off; When the actual value reaches or exceeds the lower limit set value but is still lower than the upper limit set value, the green light and red light are all turned off, the lower limit relay is always low-cut and Qualcomm, and the upper limit relay is always low-cut and high-cut; When the actual value reaches or exceeds the upper limit set value, the red light is on, and the upper and lower limit relays here are always low-off and always Qualcomm. In general, the output of the lower limit relay can be used for auxiliary heating control, the upper limit relay can be used for heating control, or the output of the lower limit relay can be used for temperature control, and the output of the upper limit relay can be used for over-temperature alarm. For instruments with suffix "f", the temperature required for the upper limit must be adjusted to be higher than the lower limit.

— 6 —

Temperature value. When the actual value is lower than the lower limit, the green light is on, and the relay is always low and hot; When the actual value is higher than the lower limit and lower than the upper limit, it is still all low-pass and the temperature rises; When the actual value is higher than the upper limit, the red light is on, the relay is always Qualcomm, always low, and the heating is stopped. Only when the actual value is lower than the lower limit, the green light is on and always low, and the whole process is repeated. There is only one relay output, which is convenient to connect with the load.

7.xmt– 13 1, 132,xmta–230 1,2302,xmtd–230 1,2302,xmt–830 1,8302。 When the actual temperature does not enter the proportional band, the green light is on, the relay is always low on and high off, and the load is hot; When entering the proportional band, the relay starts to switch regularly, and the traffic lights change periodically. The higher the temperature, the shorter the total low-pass time, and vice versa. Change the temperature of the instrument by changing the average heating power of the load, such as the instrument with overrun alarm function, such as xmta–2311,23 12, xmta-231,23 12. Other usage methods are the same as XMT- 10 1 and 102.

Verb (abbreviation of verb) matters needing attention

1. When the instrument is kept, its environment shall meet the technical requirements, and there shall be no corrosive gas on site.

2. If the instrument is damaged due to poor manufacturing quality, it will be repaired free of charge within 18 months; If it is caused by unpacking, storage or improper use, our factory is responsible for lifelong maintenance, and the user pays the repair fee as appropriate.

3. When ordering, the instrument model, graduation number and measuring range of the temperature sensing element used shall be indicated in the contract, such as XMT–101,k, 0–1300; If you need to buy temperature sensing elements, please also indicate the graduation number, specification, length, etc.

4. If the instrument is used to measure and control pressure, flow and liquid level, it shall inform the name, model and specification of the matching detection element;

5. Accessories: two sets of installers and a manual.

6. Specially recommend new products.

(1) YR series intelligent industrial temperature, pressure, flow, liquid level and humidity controllers/regulators.

Features: 1. An instrument has programmable inputs: thermocouple signals such as K, S, N, B, E, J, T and WRe, thermal resistors such as Pt 100 and Cu50, and linear input signals such as 0–5V,1–5V, mA and mV, with built-in high-precision nonlinear correction.

2. programmable output: one instrument can adapt to SSR voltage, 0~ 10 mA, 4~20 mA,

— 7 —

— 8 —

0~20 mA, SCR trigger output, relay output, etc.

3. Expert PID artificial intelligence control algorithm, parameter self-tuning, high precision and no overshoot control.

It can adapt to 4.85 v ~ 264 vac power supply, and all of them adopt imported IC chips, which has strong anti-interference performance.

5. Model and function introduction

YR508T: Intelligent P I D temperature controller (simple operation type). Programmable input of various thermocouples and thermal resistors; Modular output supports SSR voltage, relay contact switch and SCR zero-crossing trigger output; There are various alarm modes with upper and lower limits. With low price, strong function, high control precision (generally 0.65438 0℃) and strong anti-interference performance, it is an ideal product to replace imported and domestic intelligent instruments.

YR708: expert P I D artificial intelligence adjustment, transmission and communication functions

YR808: It has all the functions of YR708 and has the function of manual/automatic undisturbed bidirectional switching.

YR808P: It has all the functions of YR808 and 50-cycle program control function of Yr708m/m2: 6-channel /2-channel display alarm.

YR708H/Y: Intelligent flow totalizer with temperature and pressure compensation function.

6. Detailed instructions can be obtained from our company or distributor.

(2) YR-2/YR-3 series intelligent double digital display time relay:

Features: 1. Both the set value and the delay value are displayed.

2. Set the time range of 0.0 1 sec to 99 hours and 59 minutes. High accuracy: the daily error is less than 5 seconds.

3. There are single delay type and periodic type for you to choose from (suitable for most time control occasions).

4. Appearance size: 48×48, 48×96, 96×96, 96×48, 72×72 and other shapes are optional.

5. All-round display of working status, misoperation reminder, cheap.

(3) Programmable time controller: it controls the on-off times of equipment 64 times a day (32 segments), which is suitable for controlling the on-off times of electrical appliances (or equipment) in a daily cycle.

(4) High-precision intelligent temperature control cabinet (box). (5) Digital display current voltmeter.